Observations · sensor inputs
Latest value per channel. Each tile carries its own age and provenance — the panel is composited from separate rows, not one reading.
Climate
Nutrient
Recent observations · showing 8 of 20
| Measured at | Target | Values | Provenance |
|---|---|---|---|
| 7/25/2026 4:48:18 AM | Garage Rig — 2ft × 4ft | pH 6.10 | Measured · manual |
| 7/25/2026 4:27:37 AM | Garage Rig — 2ft × 4ft | Air 20.4 °CRH 62 %PPFD 280 µmolCO₂ 900 ppmVPD 0.90 kPaEC 1.45 mS/cmpH 5.90H₂O T 20.0 °CRes 85 % | Measured · manual |
| 7/25/2026 4:26:43 AM | B2-1 (sample/placeholder crop) | Air 22.5 °CRH 65 %EC 1.55 mS/cmpH 6.00 “Morning check, handheld meter.” | Measured · manual |
| 7/25/2026 4:26:43 AM | B2-1 (sample/placeholder crop) | Air 22.5 °CRH 65 %EC 1.55 mS/cmpH 6.00 “Morning check, handheld meter.” | Measured · manual |
| 7/25/2026 4:25:04 AM | Garage Rig — 2ft × 4ft | RH -50 % (out of range)PPFD 999999999 µmol (out of range)pH 99.00 (out of range)Res 500 % (out of range) | Demo · manual |
| 7/25/2026 4:24:24 AM | Garage Rig — 2ft × 4ft | — | Demo · manual |
| 7/4/2026 9:21:58 PM | Garage Rig — 2ft × 4ft | Air 21.0 °CRH 68 %PPFD 380 µmolCO₂ 800 ppmVPD 0.80 kPa | Demo · manual |
| 7/4/2026 9:21:58 PM | Reservoir (rack-wide) | EC 1.40 mS/cmpH 5.70H₂O T 19.0 °CRes 90 % | Demo · sensor_stub |
Read-only history. Editing or deleting a logged observation is not built in this scaffold.
Growth index
Derived from NDVI + LiDAR + leaf area over the 7-day window ending 7/4/2026.
Recommendations
Produced by a placeholder linear rule with documented coefficients — not a model trained on real data. Each card names the actuator that could carry it out, and its current mode. Botan.ai never actuates real hardware; accepting a card records your decision in the log below.
Suggest raising EC / PPM by 0.4 mS/cm toward 2.20 mS/cm. Current reading: 1.45 mS/cm.
Actuator: A/B stock doser (simulated) · Auto
Illustrative linear model: Δgrowth ≈ coef · (reading − target); placeholder coef for EC / PPM = 0.08. Not fitted on real data. Target is the midpoint of the active Fruiting (generic) profile band.
Suggest raising Water temp by 1 °C toward 21.0 °C. Current reading: 20.0 °C.
No connected actuator — this one needs a manual action in the grow room.
Illustrative linear model: Δgrowth ≈ coef · (reading − target); placeholder coef for Water temp = -0.015. Not fitted on real data. Target is the midpoint of the active Fruiting (generic) profile band.
Decision log
- 7/25/2026 4:25:40 PMaccept recommendationby human Recommend-only: decision logged; no hardware actuation.
- 7/25/2026 4:59:07 AMaccept recommendationby human Recommend-only: decision logged; no hardware actuation.
- 7/25/2026 4:50:35 AMaccept recommendationby human Recommend-only: decision logged; no hardware actuation.
- 7/25/2026 4:26:27 AMaccept recommendationby human Recommend-only: decision logged; no hardware actuation.
- 7/25/2026 4:24:02 AMaccept recommendationby human Recommend-only: decision logged; no hardware actuation.
- 7/25/2026 4:24:02 AMaccept recommendationby human Recommend-only: decision logged; no hardware actuation.
- 7/25/2026 4:23:51 AMdismiss recommendationby human Recommend-only: dismissal logged.
- 7/25/2026 4:22:43 AMaccept recommendationby human Recommend-only: decision logged; no hardware actuation.
Control & actuation
Single-step rule evaluation (documented rules, not a trained model). Each run applies at most one step per actuator.
Master mode
Crop profile
Target ranges · Fruiting (generic)
Generic starting ranges, not crop-specific agronomy — and not fitted to your rig. Photoperiod is clamped to 1–24 h when the controller applies it.
Irrigation
Lighting
Nutrient dosing
Latest control step
7/25/2026 5:03:05 AM · 39 d ago- Nutrient dosingno changeno change— Move EC target toward profile midpoint 2.20 mS/cm (from 2.20).
- Irrigationno changeno change— VPD within target — hold irrigation.
- Lightingno changeno changeclamped— PPFD 280 µmol below profile min 300 — raise lighting.
Previous 9 runs
- 7/25/2026 4:27:41 AM · auto · 1 applied
- 7/25/2026 4:27:37 AM · auto · 1 applied
- 7/25/2026 4:27:32 AM · auto · 1 applied
- 7/25/2026 4:27:18 AM · auto · 1 applied
- 7/25/2026 4:27:14 AM · auto · 1 applied
- 7/25/2026 4:27:11 AM · auto · 3 applied
- 7/25/2026 4:26:54 AM · auto · 3 applied
- 7/25/2026 4:25:56 AM · auto · 3 applied
- 7/25/2026 4:24:44 AM · manual · 0 applied
Audit log · recent actuation events· showing 10 of 34
| When | Actuator | Source | Change | Why |
|---|---|---|---|---|
| 7/25/2026 4:58:50 AM | Overhead LED array (simulated) | mode change | mode: manual → auto | Mode changed manual → autoby human |
| 7/25/2026 4:58:17 AM | Overhead LED array (simulated) | safety clamp | Level (%): 15 → 100 | Override clamped to safe bounds [0, 100] %by human |
| 7/25/2026 4:58:17 AM | Overhead LED array (simulated) | manual | Level (%): 15 → 100 | Manual override from UIby human |
| 7/25/2026 4:57:37 AM | Overhead LED array (simulated) | mode change | mode: auto → manual | Mode changed auto → manualby human |
| 7/25/2026 4:36:42 AM | Overhead LED array (simulated) | mode change | mode: manual → auto | Mode changed manual → autoby human |
| 7/25/2026 4:36:22 AM | Overhead LED array (simulated) | mode change | mode: auto → manual | Mode changed auto → manualby human |
| 7/25/2026 4:27:41 AM | Overhead LED array (simulated) | auto | Level (%): 0 → 15 | PPFD 280 µmol below profile min 300 — raise lighting.by controller |
| 7/25/2026 4:27:36 AM | Top-drip pump loop (simulated) | auto | Interval (min): 105 → 115 | VPD 0.80 kPa below profile min 0.9 — lengthen interval.by controller |
| 7/25/2026 4:27:32 AM | Top-drip pump loop (simulated) | auto | Interval (min): 95 → 105 | VPD 0.80 kPa below profile min 0.9 — lengthen interval.by controller |
| 7/25/2026 4:27:18 AM | Top-drip pump loop (simulated) | auto | Interval (min): 85 → 95 | VPD 0.80 kPa below profile min 0.9 — lengthen interval.by controller |
Simulated actuation — not connected to real hardware or sensors. Each run evaluates documented rules once against the latest reading and applies at most one step; readings do not respond to actuation, so repeated runs step in the same direction.
Rig configuration
Hanging vertical hydroponics · Rack → Rows → Tubes → Plant sites. Sites are named row-tube-site, e.g. A1-3.
Row A
Row B
Row C